中韩高清无专码区2021曰_色翁荡熄又大又硬又粗又视频图片_波多野结衣乳巨码无在线观看_国产91福利在线播放_国产人妻人伦精品_马来西亚潜水天堂_黄色免费网站下载_免费看黄网站黄污污污热门软件_小莹客厅激情46章至50章视频

China Air Conditioning Automatic Control System, PLC Automation Control System, Building BA Automatic Control System - China Supplier
China Air Conditioning Automatic Control System, PLC Automation Control System, Building BA Automatic Control System - China Supplier China Air Conditioning Automatic Control System, PLC Automation Control System, Building BA Automatic Control System - China Supplier

Air Conditioning Automatic Control System, PLC Automation Control System, Building BA Automatic Control System

Price:Negotiable
Industry Category: Instruments & Meters/Automation Control Systems/PLC & Control Systems
Product Category:
Brand: 亞川科技
Spec:


Contact Info
  • Add:西安市翠華南路60號, Zip: 710061
  • Contact: 仵小玲
  • Tel:13891834587
  • Email:[email protected]

Other Products

Description
Additional Information

Building Automation System (BAS) Control System

Detailed Introduction to Air Conditioning Automation System, PLC Automation Control System, and Building BA Control System

A Building Automation System (BAS), also known as BA, is a building management and control system that centralizes the monitoring, management, and decentralized control of various distributed equipment within a building or building complex. This includes power distribution, lighting, elevators, air conditioning, heating, water supply and drainage, fire protection, security, and more. It oversees equipment operation, safety status, energy usage, and energy-saving management.

BAS Monitoring Functions for Building Equipment:

(1) Monitored parameters: room temperature, humidity, pressure difference, filter pressure difference.

(2) Safety protection function: filter clogging alarm.

(3) Remote control function: opening and closing of electric airtight valves.

(4) Control requirement: maintain positive pressure in the room relative to the corridor.

(5) Automatic adjustment function: automatically adjust exhaust valves based on pressure difference requirements.

BAS Monitoring Functions for Air Handling Units (Supply Fans):

(1) Monitored parameters: indoor and outdoor temperature and humidity; supply air temperature and humidity; filter pressure difference; start/stop status and operating parameters of fans, water valves, air dampers, etc.; status of freeze protection switches; duct static pressure, operating frequency.

(2) Safety protection functions: fan fault alarm; air filter clogging alarm; freeze protection alarm and automatic protection function; when electric heating is used in the air conditioning system, no-air power-off and over-temperature power-off measures should be implemented; when electric humidifiers are used, waterless power-off protection and alarm devices should be installed.

(3) Remote control function: start/stop fans; adjust the opening of water valves and air dampers and monitor valve position feedback.

(4) Automatic start/stop function: when the fan stops, the fresh/supply air damper and water valve interlock and close; start/stop fans according to a schedule.

(5) Interlock with exhaust fans: start: supply first, then exhaust; stop: exhaust first, then supply.

(6) Automatic adjustment function: automatically adjust the opening of water valves; automatically adjust the opening of air dampers; automatically control electric heating and humidification equipment; automatically adjust fan speed based on duct static pressure to maintain the static pressure at a set value; set and modify cooling/heating/transition season operating modes; set and modify the setpoints for air temperature and humidity in the service area.

BAS Monitoring Functions for Changing Rooms and Buffer Rooms:

(1) Monitored parameters: room pressure difference, filter pressure difference.

(2) Safety protection function: filter clogging alarm.

(3) Remote control function: opening and closing of electric airtight valves.

(4) Control requirements: maintain negative pressure in changing and exit buffer rooms relative to the corridor, and positive pressure relative to the environment; maintain positive pressure in room buffers relative to the corridor.

(5) Automatic adjustment function: automatically adjust exhaust valves based on pressure difference requirements.

BAS Monitoring Functions for Exhaust Fans:

(1) Monitored parameters: fan start/stop and fault status; filter pressure difference switch status; duct static pressure and motor frequency.

(2) Safety protection functions: fan fault alarm; filter clogging alarm.

(3) Remote control function: start/stop fans.

(4) Interlock with air handling units (supply fans): start: supply first, then exhaust; stop: exhaust first, then supply.

(5) Automatic adjustment function: automatically adjust fan speed based on duct static pressure to maintain the static pressure at a set value.

Consultation Information:

For more information on building automation control system products and solution pricing, please call.

Contact: Manager Wu

Phone: 13891834587 (also on WeChat)

Q Q: 704151787

Email: [email protected]

Services Provided:

Provide project configuration and detailed solution pricing

Provide drawing refinement solutions

Provide various technical support and coordination

Industry Category Instruments & Meters/Automation Control Systems/PLC & Control Systems
Product Category
Brand: 亞川科技
Spec:
Stock:
Origin: China / Shaanxi / Xianshi
About Toocle.com -  Toocle Partnership -  Toocle Services -  Toocle Agents -  Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經營性-2023-0192
ChatGlobal Chat Now