China Sacrificial Anode Test Pile | Custom Pipeline Test Pile - China Supplier China Sacrificial Anode Test Pile | Custom Pipeline Test Pile - China Supplier China Sacrificial Anode Test Pile | Custom Pipeline Test Pile - China Supplier China Sacrificial Anode Test Pile | Custom Pipeline Test Pile - China Supplier China Sacrificial Anode Test Pile | Custom Pipeline Test Pile - China Supplier

Sacrificial Anode Test Pile | Custom Pipeline Test Pile

Price:Negotiable
Industry Category: Construction & Building Materials/Piping Systems/Cathodic Protection Devices
Product Category:
Brand:
Spec:


Contact Info
  • Address:武陟縣陽(yáng)魁路中段南側(cè), Zip:
  • Contact: 常晴
  • Tel:0391-2098555
  • Email:

Other Products

Description
Additional Information

Sacrificial Anode Test Station | Custom Pipeline Test Stations

Product Introduction:

Test stations, also known as inspection posts, can be categorized by material into steel test stations, cement test stations, plastic-steel test stations, and carbon steel test stations. Based on usage environment, they can be divided into urban network test stations and buried pipeline test stations, among others. They are primarily used for detecting cathodic protection parameters and are essential devices in pipeline management and maintenance, deployed along the pipeline according to testing functions. Test stations can be used to measure pipeline potential, current, and insulation performance, as well as for coating leak detection and testing for AC/DC interference.

Our company designs anti-theft and explosion-proof test stations, as well as multi-functional defensive test stations based on client requirements. Using advanced processes, the surfaces are spray-coated and galvanized to effectively prevent corrosion of the test stations during use. Our test stations employ seamless welding technology, ensuring durability and an aesthetically pleasing appearance, making them an ideal choice for cathodic protection parameter testing. Description of Steel Pipe Test Stations:

Our company produces steel pipe test stations, mainly including standard steel pipe test stations and rainproof steel pipe test stations. Common specifications are as follows:

Test Station Type  Diameter  Length 

Steel Pipe Test Station  Φ 108  1.5 m - 3 m 

Rainproof Test Station  Φ 108  1.5 m - 3 m 

Test stations are used for detecting cathodic protection parameters and are critical devices in pipeline management and maintenance. They are employed for measuring cathodic protection potential, current, and insulation performance, as well as for coating leak detection and testing for AC/DC interference.

Classification of Test Stations: 
1. By material: Steel test stations, cement test stations, plastic test stations. Steel test stations are further divided into carbon steel test stations and stainless steel test stations.  
2. By function:  
● Potential test stations: Mainly used for detecting protection potential.  
● Sacrificial anode test stations: Used to connect sacrificial anodes and measure their performance parameters. 
● Current test stations: Measure current in the pipeline. 
● Protection effectiveness test stations: Connect to test coupons.
III. Significance of Test Stations in Cathodic Protection
To measure the potential, current, and resistance of structures, cathodic protection test stations must be installed. There are no better alternative measuring devices available for this purpose. For pipeline potential test stations, one station every 1–2 km is sufficient, and generally, for every five potential test stations, one pipeline current measurement station should be installed. In densely built urban areas, the spacing for potential measurement stations is approximately half a kilometer. Conversely, above-ground electrical insulation measurement stations are required at buried electrical insulation points. Measurement stations should also be installed at crossing points with DC traction systems. If necessary (e.g., on high-resistance fixed surfaces), fixed measurement points for structure potential should be established.
IV. Post-Installation Maintenance of Test Stations
1) Check the insulation condition between the terminal and the ground; the resistance value should be greater than 100 kΩ. Measure with a multimeter. If the value is lower, inspect whether the terminal is grounded with the outer steel pipe. If so, replace or repair it.
2) Test stations should be painted and renumbered annually.
3) Prevent damage or loss of test stations. Conduct educational campaigns for residents and children along the pipeline to promote the protection of national property.

Industry Category: Construction & Building Materials/Piping Systems/Cathodic Protection Devices
Product Category:
Brand:
Spec:
Stock:
Origin:
Storefront Language: English English Chinese
About Toocle.com -  Toocle Partnership -  Toocle Services -  Toocle Agents
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營(yíng)性-2023-0192
ChatGlobal Chat Now 双柏县| 文昌市| 福泉市| 绥德县| 宁国市| 通辽市| 会泽县| 建昌县| 昭平县| 高唐县| 咸丰县| 平远县| 滁州市| 台南市| 永德县| 四子王旗| 三穗县| 启东市| 镇赉县| 通城县| 扎赉特旗| 海淀区| 望城县| 望江县| 长宁县| 文成县| 徐闻县| 法库县| 西丰县| 汶上县| 滦平县| 新化县| 双流县| 洞口县| 上犹县| 勐海县| 七台河市| 大埔县| 若羌县| 渭源县| 丁青县|