China ST-1513 Fully Automatic Micro Moisture Analyzer - China Supplier
China ST-1513 Fully Automatic Micro Moisture Analyzer - China Supplier

ST-1513 Fully Automatic Micro Moisture Analyzer

Price:Negotiable
Industry Category: Instruments & Meters/Analytical Instruments/Moisture Meters
Product Category:
Brand:
Spec:


Contact Info
  • Address:北京市昌平區(qū)沙河鎮(zhèn)小李莊村東2幢225室, Zip:
  • Contact: 李
  • Tel:15037816059
  • Email:[email protected]

Other Products

Description
Additional Information

ST-1513 Fully Automatic Trace Moisture Analyzer

Product Introduction:

The ST-1513 Fully Automatic Trace Moisture Analyzer employs the Karl Fischer Coulometric method to detect trace moisture content in solids, liquids, and gases. It can rapidly determine the moisture content in chemicals, petroleum products, pharmaceuticals, pesticides, and other products such as alcohols, oils, fats, ethers, esters, acids, alkanes, benzenes, amines, organic solvents, phenols, and pharmaceutical raw materials. With advantages including high measurement accuracy, fast speed, and stable and reliable data, the ST-1513 Fully Automatic Trace Moisture Analyzer is widely used in petroleum, chemical, power, environmental protection, universities, medical, and other sectors.

Manufacturer: 

Beijing Xuxin Instrument Equipment Co., Ltd.

Applicable Standards:

GB/T 6283-2008 Determination of moisture content in chemical products - Karl Fischer method
GB/T 7600-1987 Determination of water content in transformer oils in service (Coulometric method)
ISO 10337-1997 Determination of water in crude oil - Karl Fischer coulometric titration method
GB/T 11146-2009 Determination of water content in crude oil - Karl Fischer coulometric titration method
GB/T 3727-2003 Determination of trace water in ethylene and propylene for industrial use
GB/T 5074-1985 Microcoulometric method for determination of water content in coking products
GB/T 6023-2008 Determination of trace water in butadiene for industrial use - Karl Fischer coulometric method
GB/T 7376-2008 Determination of trace water in fluoroalkanes for industrial use - Karl Fischer method
GB/T 18619.1-2002 Determination of water content in natural gas - Karl Fischer coulometric method
GB/T 18826-2002 1,1,1,2-Tetrafluoroethane for industrial use

GB/T11133-2015 Determination of water content in petroleum products, lubricants, and additives - Karl Fischer coulometric titration method
SH/T 0246-1992 Determination of water content in light petroleum products (Electrometric method)
SH/T 0255-1992 Determination of water in additives and additive-containing lubricants (Electrometric method)
ASTM E1064-2008 Determination of water in organic liquids by coulometric Karl Fischer titration
ASTM D4928-00 (2010) Determination of water in crude oil by coulometric Karl Fischer titration ASTM E1064-2008 Determination of water in organic liquids by coulometric Karl Fischer titration

ASTM D4928-00 (2010) Determination of water in crude oil by coulometric Karl Fischer titration
ASTM D6304-2007 Determination of water in petroleum products, lubricants, and additives by coulometric Karl Fischer titration, etc.

Features:

l Color high-definition LCD touch screen, easy to operate

l Blank current compensation and equilibrium point drift compensation to correct measurement results

l Dual-circuit balanced titration for smaller test result errors and higher sensitivity

l Electrolytic cell adopts waterproof sealing design, with short equilibrium time and longer electrolyte service life

l Electrolysis delay function and endpoint delay function, suitable for low moisture content or special sample detection

l 8 formula options, display units (ug, mg/L, ppm, %) can be memorized

l Reagent failure detection prompt for improved convenience and user-friendliness

l Can store 1000 test records for easy future reference

l Full Chinese/Full English interface display (optional)

l Paid provision of metrology certificate from the Institute of Metrology Science

Technical Parameters:

Measurement Principle

Coulometric titration (Coulometric analysis)

Display Method

LCD touch screen

Measurement Range

1ug~200mg

Water Content Range

0.0001%(1ppm)~99.99%

Precision

For test water volume between 10ug~1000ug   Error less than ±3ug

For test water volume greater than 1000ug          Error less than ±0.3%

Resolution

0.1ug

Power

≤60W

Stirring

Electromagnetic stirring (adjustable speed)

Electrolysis Current

0~400mA (automatic control)

Electrolysis Speed

2.2mg/min (0~37ug/s automatic control)

Printing

Automatic printing of results and test information

Ambient Temperature

5℃~40℃

Relative Humidity

10%~80%Rh

Power Supply

220V±10% 50Hz

Dimensions

330mm *260mm *220mm

Weight

4.14Kg


Industry Category: Instruments & Meters/Analytical Instruments/Moisture Meters
Product Category:
Brand:
Spec:
Stock:
Origin:
Storefront Language: English English Chinese
About Toocle.com -  Toocle Partnership -  Toocle Services -  Toocle Agents
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營性-2023-0192
ChatGlobal Chat Now 青田县| 股票| 大荔县| 西峡县| 全州县| 宁远县| 马龙县| 南召县| 东乌珠穆沁旗| 翁源县| 安庆市| 会宁县| 沙湾县| 富源县| 庄河市| 三原县| 九龙坡区| 泽库县| 大化| 惠州市| 独山县| 绥棱县| 江川县| 五台县| 中阳县| 垣曲县| 新营市| 板桥市| 吉水县| 黎城县| 德保县| 都江堰市| 盱眙县| 丘北县| 墨竹工卡县| 井研县| 都兰县| 江阴市| 大厂| 板桥市| 武鸣县|